Constrained molecular dynamics calculations

From VASP Wiki
Revision as of 15:42, 24 February 2025 by Csheldon (talk | contribs) (Csheldon moved page Constrained molecuar dynamics calculations to Constrained molecular dynamics calculations: Misspelled title)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Geometric constraints are introduced by defining one or more entries with the STATUS parameter set to 0 in the ICONST-file. Constraints can be used within a standard NVT or NpT MD setting introduced by MDALGO=1|2|3. Note that fixing geometric parameters related to lattice vectors is not allowed within an NVT simulation (VASP would terminate with an error message). Constraints can be combined with restraints, time-dependent bias potentials (Metadynamics), monitored coordinates and other elements available within the context of MD.