EFIELD = [real] 

Description: EFIELD controls the size of the applied electric field.


It is possible to apply an external electrostatic field in slab, or molecular calculations. Presently only a single value can be supplied and the field is applied in the direction selected by IDIPOL=1-3. The field is supplied in units of eV/Å. Dipole corrections to the potential (LDIPOL=.TRUE.) can and should be turned on to avoid interactions between the periodically repeated images.

Related Tags and Sections

Monopole Dipole and Quadrupole_corrections, NELECT, EPSILON, IDIPOL, DIPOL, LMONO, LDIPOL