{{DEF|ISIF|0|for {{TAG|IBRION}}{{=}}0 (molecular dynamics) or {{TAG|LHFCALC}}{{=}}.TRUE.|2|else}} | {{DEF|ISIF|0|for {{TAG|IBRION}}{{=}}0 (molecular dynamics) or {{TAG|LHFCALC}}{{=}}.TRUE.|2|else}} | ||
Description: | Description: Determines if the stress tensor is calculated and which ionic degrees of freedom are varied. | ||
---- | ---- | ||
{{TAG|ISIF}} | For {{TAG|ISIF}}<math>\ge</math>2, the stress tensor is calculated. It is defined as the negative of the derivative of the energy | ||
<math> E </math> | |||
with respect to the strain tensor <math> \epsilon_{ij} </math>: | |||
:<math> \sigma_{ij} = - \frac{\delta E} {\delta \epsilon_{ij}} </math> | |||
This might be different from other first principles codes. | |||
A positive in the diagonals means that the system is under compressive strain and wants to expand. A negative value implies that the system is under tensile strain and wants to reduce its volume. | |||
The calculation of the stress tensor is relatively time-consuming, and, therefore, by default, it is switched off in some cases. The forces are always calculated. | |||
{{TAG|ISIF}} also determines which degrees of freedom (ionic positions, cell volume, and cell shape) of the structure are allowed to change. | |||
:{| cellpadding="5" cellspacing="0" border="1" | :{| cellpadding="5" cellspacing="0" border="1" | ||
|{{TAG|ISIF}} ||colspan="2" style="text-align: center;"| calculate ||colspan="3" style="text-align: center;"| degrees-of-freedom | |{{TAG|ISIF}} ||colspan="2" style="text-align: center;"| calculate ||colspan="3" style="text-align: center;"| degrees-of-freedom | ||
|- | |- | ||
| || forces || | | || forces || stress tensor || positions || cell shape || cell volume | ||
|- | |- | ||
| 0 || yes || no || yes || no || no | | 0 || yes || no || yes || no || no | ||
Line 37: | Line 40: | ||
| 8 || yes || yes || yes || no || yes | | 8 || yes || yes || yes || no || yes | ||
|} | |} | ||
* For {{TAG|ISIF}}=1, only the trace of the stress tensor is calculated. This means only the total pressure is correct and can be read off in the line: | |||
For {{TAG|ISIF}}=1, only the trace of the stress tensor is calculated. This means only the total pressure is correct and can be read off in the line: | |||
external pressure = ... kB | external pressure = ... kB | ||
The individual components of the stress tensor are not reliable in this case and must be disregarded. | :The individual components of the stress tensor are not reliable in this case and must be disregarded. | ||
* Accuracy | |||
{{NB|warning|The PAW basis for the [[Category:Electronic minimization|electronic minimization]] is not adjusted when the structure is varied during a calculation.|:}} | |||
{{NB| | :Therefore, carefully consider effects such as [[Energy_vs_volume_Volume_relaxations_and Pulay_stress|Pulay stress]] and choose generous settings for the [[Category:Electronic minimization|electronic minimization]]. Generally, volume changes should be done only with an increased energy cutoff, e.g., {{TAG|ENCUT}}{{=}}1.3×max({{TAG|ENMAX}}), and {{TAG|PREC}}{{=}}High. | ||
{{ | * To further control the ionic degrees of freedom that can vary during the calculation, set `Selective dynamics` in the {{FILE|POSCAR}} file. | ||
* ISIF{{=}}8 is only available as of VASP.6.4.1. | |||
== Related tags and articles == | == Related tags and articles == | ||
{{TAG|IBRION}}, | {{TAG|IBRION}}, | ||
[[:Category:Ensembles| Ensembles]], | |||
{{ | Selective-dynamics mode of the {{FILE|POSCAR}} file | ||
{{sc|ISIF|Examples|Examples that use this tag}} | {{sc|ISIF|Examples|Examples that use this tag}} |
Revision as of 10:51, 3 October 2023
ISIF = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8
Default: ISIF | = 0 | for IBRION=0 (molecular dynamics) or LHFCALC=.TRUE. |
= 2 | else |
Description: Determines if the stress tensor is calculated and which ionic degrees of freedom are varied.
For ISIF2, the stress tensor is calculated. It is defined as the negative of the derivative of the energy with respect to the strain tensor :
This might be different from other first principles codes. A positive in the diagonals means that the system is under compressive strain and wants to expand. A negative value implies that the system is under tensile strain and wants to reduce its volume. The calculation of the stress tensor is relatively time-consuming, and, therefore, by default, it is switched off in some cases. The forces are always calculated.
ISIF also determines which degrees of freedom (ionic positions, cell volume, and cell shape) of the structure are allowed to change.
ISIF calculate degrees-of-freedom forces stress tensor positions cell shape cell volume 0 yes no yes no no 1 yes trace only yes no no 2 yes yes yes no no 3 yes yes yes yes yes 4 yes yes yes yes no 5 yes yes no yes no 6 yes yes no yes yes 7 yes yes no no yes 8 yes yes yes no yes
- For ISIF=1, only the trace of the stress tensor is calculated. This means only the total pressure is correct and can be read off in the line:
external pressure = ... kB
- The individual components of the stress tensor are not reliable in this case and must be disregarded.
- Accuracy
Warning: The PAW basis for the is not adjusted when the structure is varied during a calculation.
- Therefore, carefully consider effects such as Pulay stress and choose generous settings for the. Generally, volume changes should be done only with an increased energy cutoff, e.g., ENCUT=1.3×max(ENMAX), and PREC=High.
- To further control the ionic degrees of freedom that can vary during the calculation, set `Selective dynamics` in the POSCAR file.
- ISIF=8 is only available as of VASP.6.4.1.
Related tags and articles
IBRION, Ensembles, Selective-dynamics mode of the POSCAR file