XAS theory: Difference between revisions
No edit summary |
|||
(17 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
X-ray absorption near-edge spectroscopy (XANES) is a very strong (and experimentally heavily used) method for the characterization of materials. | X-ray absorption near-edge spectroscopy (XANES) is a very strong (and experimentally heavily used) method for the characterization of materials. | ||
The simulation involves the excitation of a core electron into valence/conduction bands. Since for most semiconductors and insulators the electron stays strongly localized on the atom, the inclusion electron-hole interactions in the calculations is absolutely crucial. For this means two methods are mainly used: | The simulation involves the excitation of a core electron into valence/conduction bands. Since for most semiconductors and insulators the electron stays strongly localized on the atom, the inclusion electron-hole interactions in the calculations is absolutely crucial. For this means two methods are mainly used: | ||
*Super-cell core-hole (SCH) method. | *Super-cell core-hole (SCH) method {{cite|karsai:prb:2018}}. | ||
*Bethe-Salpeter equation (BSE) method. | *Bethe-Salpeter equation (BSE) method. | ||
== Super-cell core-hole mehod == | == Super-cell core-hole mehod == | ||
In this method a chosen core electron is removed from the core leaving behind a positive charge. Since one wants simulate the excitation of this electron into energetically higher lying states, one electron is added to valence/conduction bands resembling the final state of the excitation process (this is also referred to final state approximation). With this setup a fully self-consistent electronic minimization is carried out. The core hole is perfectly screened by the other electrons in metals so there should no difference between core-hole calculations and regular calculations. In semiconductors and insulators this screening is very weak and very strong attraction between the electrons and hole occur which results not only in a lowering of the excited states compared to the valence states but a very strong change of the valence/conduction band structure. Hence the relaxation of the valence/conduction electrons is the main effect in core-hole calculations. Fortunately the relaxation of the core states in core-hole calculations is negligible. This makes the implementation into a PAW framework smooth, since no on-the fly recalculation of PAW potentials is needed in every step of the electronic self-consistent cycle. | |||
'''Very important''' is that a sufficiently large super cell is needed to minimize the interaction of neighboring core holes within periodic boundary conditions. Hence the computational expense within this methods comes mainly from the use of large super cells. Nevertheless this method is usually still computationally cheaper than the BSE method for core electrons. | |||
=== Dielectric function used in the SCH method === | |||
Since the wave length of the electromagnetic waves in absorption spectroscopy is usually much larger than the characteristic momentum in solids, we start from the transversal expression for the imaginary part of the dielectric function in the long wavelength limit (<math>\mathbf{q}=0</math>) which is directly proportional to the absorption spectrum | |||
<math> | |||
\epsilon_{\alpha \beta}^{(2)} (\omega,\mathbf{q}=0) = \frac{4 \pi^{2} e^{2} \hbar^{4}}{\Omega \omega^{2} m_{e}^{2}} \sum\limits_{c,v,\mathbf{k}} 2w_{\mathbf{k}} \delta(\varepsilon_{c\mathbf{k}}-\varepsilon_{v\mathbf{k}}-\omega) \times M_{\alpha}^{v\rightarrow c} {M_{\beta}^{v\rightarrow c}}^{*} | |||
</math> | |||
where <math>M</math> and <math>\varepsilon</math> denote momentum matrix elements and orbital energies. | |||
Here we consider excitations only between valence (<math>v</math>) and conduction (<math>c</math>) bands. The components of the dielectric tensor are indexed by the Cartesian indices <math>\alpha</math> and <math>\beta</math>. <math>\Omega</math>, <math>e</math> and <math>m_{e}</math> denote the unit cell volume, electron charge and mass of the electron, respectively. In the PAW method the all-electron orbitals <math>|\psi_{n\bold{k}}\rangle</math> are given by a linear transformation of the pseudo orbitals <math>|\tilde{\psi}_{n\bold{k}}\rangle</math>: | |||
<math> | |||
|\psi_{n\bold{k}}\rangle = |\tilde{\psi}_{n\bold{k}}\rangle + \sum\limits_{i} (|\phi_{i}\rangle - |\tilde{\phi}_{i}\rangle) \langle \tilde{p}_{i} |\tilde{\psi}_{n\bold{k}}\rangle. | |||
</math> | |||
The pseudo orbitals depend on the band index <math>n</math> and crystal momentum <math>\bold{k}</math>. <math>|\phi_{i}\rangle</math>, <math>|\tilde{\phi}_{i}\rangle</math> and <math>|\tilde{p}_{i}\rangle</math> are all-electron partial waves, pseudo partial waves | |||
and the projectors, respectively. | |||
The index <math>i</math> is a shorthand for the atomic site and other indices enumerating these quantities | |||
at each site (such as angular and magnetic quantum numbers). In the PAW formalism, the matrix elements are given by | |||
<math> | |||
M_{\alpha}^{v\rightarrow c} = \langle \psi_{c \mathbf{k}} |i \nabla_{\alpha} - \mathbf{k}_{\alpha}| \psi_{v\mathbf{k}} \rangle = \langle \tilde{\psi}_{c\mathbf{k}}| i \nabla_{\alpha}-\mathbf{k}_{\alpha}|\tilde{\psi}_{v\mathbf{k}} \rangle + \sum\limits_{ij} \langle \tilde{\psi}_{c\mathbf{k}} | \tilde{p}_{i} \rangle \langle \tilde{p}_{j} | \tilde{\psi}_{v\mathbf{k}} \rangle i \left(\langle \phi_{i}| \nabla_{\alpha}| \phi_{j} \rangle - \langle \tilde{\phi}_{i}| \nabla_{\alpha}| \tilde{\phi}_{j} \rangle \right). | |||
</math> | |||
where the one-center terms are calculated within the PAW sphere for each atom. | |||
Since in X-ray absorption spectroscopy, one only considers one core hole at a single site, | |||
we can from now on restrict the equations to a single site. The index <math>i</math> then | |||
only enumerates the main quantum number, the angular and the magnetic quantum numbers. | |||
As usual in the PAW method, using the completeness relation, <math>\sum_{i} |\tilde{p}_{i}\rangle \langle \tilde{\phi}_{i}| = 1</math>, the first and third term in the previous equation cancel each other leading to the following simplified matrix elements | |||
<math> | |||
M^{\mathrm{core}\rightarrow c\mathbf{k}}_{\alpha}=\sum\limits_{i}\langle \tilde{\psi}_{c\mathbf{k}} | \tilde{p}_{i} \rangle \langle\phi_{i}| \nabla_{\alpha}| \phi_{\mathrm{core}}\rangle. | |||
</math> | |||
Also the summation over bands can be limited to the conduction bands <math>c</math> | |||
<math> | |||
\epsilon_{\alpha \beta}^{(2)} (\omega) = \frac{4 \pi^{2} e^{2} \hbar^{4}}{\Omega \omega^{2} m_{e}^{2}} \sum\limits_{c,\mathbf{k}} 2w_{\mathbf{k}}\delta(\varepsilon_{c\mathbf{k}}-\varepsilon_{\mathrm{core}}-\omega) \times M^{\mathrm{core}\rightarrow c\mathbf{k}}_\alpha {M^{\mathrm{core}\rightarrow c\mathbf{k}}_\beta}^*. | |||
</math> | |||
== References == | |||
<references/> | |||
<noinclude> | |||
---- | |||
[[Category:Linear response]][[Category:Dielectric properties]][[Category:XAS]][[Category:Theory]] |
Latest revision as of 07:50, 19 July 2022
X-ray absorption near-edge spectroscopy (XANES) is a very strong (and experimentally heavily used) method for the characterization of materials. The simulation involves the excitation of a core electron into valence/conduction bands. Since for most semiconductors and insulators the electron stays strongly localized on the atom, the inclusion electron-hole interactions in the calculations is absolutely crucial. For this means two methods are mainly used:
- Super-cell core-hole (SCH) method [1].
- Bethe-Salpeter equation (BSE) method.
Super-cell core-hole mehod
In this method a chosen core electron is removed from the core leaving behind a positive charge. Since one wants simulate the excitation of this electron into energetically higher lying states, one electron is added to valence/conduction bands resembling the final state of the excitation process (this is also referred to final state approximation). With this setup a fully self-consistent electronic minimization is carried out. The core hole is perfectly screened by the other electrons in metals so there should no difference between core-hole calculations and regular calculations. In semiconductors and insulators this screening is very weak and very strong attraction between the electrons and hole occur which results not only in a lowering of the excited states compared to the valence states but a very strong change of the valence/conduction band structure. Hence the relaxation of the valence/conduction electrons is the main effect in core-hole calculations. Fortunately the relaxation of the core states in core-hole calculations is negligible. This makes the implementation into a PAW framework smooth, since no on-the fly recalculation of PAW potentials is needed in every step of the electronic self-consistent cycle.
Very important is that a sufficiently large super cell is needed to minimize the interaction of neighboring core holes within periodic boundary conditions. Hence the computational expense within this methods comes mainly from the use of large super cells. Nevertheless this method is usually still computationally cheaper than the BSE method for core electrons.
Dielectric function used in the SCH method
Since the wave length of the electromagnetic waves in absorption spectroscopy is usually much larger than the characteristic momentum in solids, we start from the transversal expression for the imaginary part of the dielectric function in the long wavelength limit () which is directly proportional to the absorption spectrum
where and denote momentum matrix elements and orbital energies. Here we consider excitations only between valence () and conduction () bands. The components of the dielectric tensor are indexed by the Cartesian indices and . , and denote the unit cell volume, electron charge and mass of the electron, respectively. In the PAW method the all-electron orbitals are given by a linear transformation of the pseudo orbitals :
The pseudo orbitals depend on the band index and crystal momentum . , and are all-electron partial waves, pseudo partial waves and the projectors, respectively. The index is a shorthand for the atomic site and other indices enumerating these quantities at each site (such as angular and magnetic quantum numbers). In the PAW formalism, the matrix elements are given by
where the one-center terms are calculated within the PAW sphere for each atom.
Since in X-ray absorption spectroscopy, one only considers one core hole at a single site, we can from now on restrict the equations to a single site. The index then only enumerates the main quantum number, the angular and the magnetic quantum numbers. As usual in the PAW method, using the completeness relation, , the first and third term in the previous equation cancel each other leading to the following simplified matrix elements
Also the summation over bands can be limited to the conduction bands
References