Be careful with the default smearing method (ISMEAR=1): Difference between revisions

From VASP Wiki
(Created page with "The default for {{TAG|ISMEAR}} is 2 in VASP. ---- Category:Calculational issues")
 
 
(3 intermediate revisions by 2 users not shown)
Line 1: Line 1:
The default for {{TAG|ISMEAR}} is 2 in VASP.
The default for {{TAG|ISMEAR}} is 1 in VASP. This setting is not appropriate for
insulators and semiconductors, and can results in one-electron occupancies that
are larger than 1 (2 for non spinpolarized) systems, and conversely
some states being occupied by less than 1 electron close to the Fermi-level.
It is strongly recommended to set {{TAG|ISMEAR}}=0 in the INCAR file
and use a small width {{TAG|SIGMA}}=0.05 (do not make SIGMA too small,
values below 0.001 can also lead to undesirable symmetry breaking).
 
Read more on this in {{TAG|Number of k points and method for smearing}}!
 


----
----
[[Category:Calculational issues]]
[[Category:Common Pitfalls]]

Latest revision as of 12:06, 3 November 2020

The default for ISMEAR is 1 in VASP. This setting is not appropriate for insulators and semiconductors, and can results in one-electron occupancies that are larger than 1 (2 for non spinpolarized) systems, and conversely some states being occupied by less than 1 electron close to the Fermi-level. It is strongly recommended to set ISMEAR=0 in the INCAR file and use a small width SIGMA=0.05 (do not make SIGMA too small, values below 0.001 can also lead to undesirable symmetry breaking).

Read more on this in Number of k points and method for smearing!