ISIF: Difference between revisions
(Use more TAGO) |
|||
(One intermediate revision by one other user not shown) | |||
Line 52: | Line 52: | ||
== Related tags and articles == | == Related tags and articles == | ||
{{TAG|IBRION}}, | {{TAG|IBRION}}, | ||
[[structure optimization]], | |||
[[:Category:Ensembles| Ensembles]], | [[:Category:Ensembles| Ensembles]], | ||
Selective-dynamics mode of the {{FILE|POSCAR}} file | Selective-dynamics mode of the {{FILE|POSCAR}} file, | ||
{{TAG|LATTICE_CONSTRAINTS}} | |||
{{sc|ISIF|Examples|Examples that use this tag}} | {{sc|ISIF|Examples|Examples that use this tag}} |
Latest revision as of 11:49, 18 October 2024
ISIF = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8
Default: ISIF | = 0 | for IBRION = 0 (molecular dynamics) or LHFCALC = .TRUE.
|
= 2 | else |
Description: Determines if the stress tensor is calculated and which ionic degrees of freedom are varied.
For ISIF2, the stress tensor is calculated. It is defined as the negative of the derivative of the energy with respect to the strain tensor :
- .
This might be different from other first principles codes. A positive in the diagonals means that the system is under compressive strain and wants to expand. A negative value implies that the system is under tensile strain and wants to reduce its volume. The stress tensor is symmetric , and, thus, it has six independent entries. The calculation of the stress tensor is relatively time-consuming, and, therefore, by default, it is switched off in some cases. The forces are always calculated.
ISIF also determines which degrees of freedom (ionic positions, cell volume, and cell shape) of the structure are allowed to change.
ISIF calculate degrees-of-freedom forces stress tensor positions cell shape cell volume 0 yes no yes no no 1 yes trace only yes no no 2 yes yes yes no no 3 yes yes yes yes yes 4 yes yes yes yes no 5 yes yes no yes no 6 yes yes no yes yes 7 yes yes no no yes 8 yes yes yes no yes
- For
ISIF = 1
, only the trace of the stress tensor is calculated. This means only the total pressure is correct and can be read off in the line:
external pressure = ... kB
- The individual components of the stress tensor are not reliable in this case and must be disregarded.
- Accuracy
Warning: The PAW basis for the electronic minimization is not adjusted when the structure is varied during a calculation.
- Therefore, carefully consider effects such as Pulay stress and choose generous settings for the electronic minimization. Generally, volume changes should be done only with an increased energy cutoff, e.g.,
ENCUT = 1.3×max(ENMAX)
, andPREC = High
.
- To further control the ionic degrees of freedom that can vary during the calculation, set `Selective dynamics` in the POSCAR file.
ISIF = 8
is only available as of VASP.6.4.1.
Related tags and articles
IBRION, structure optimization, Ensembles, Selective-dynamics mode of the POSCAR file, LATTICE_CONSTRAINTS