Line 3: Line 3:
Description: {{TAG|MIXPRE}} specifies the metric in the Broyden mixing scheme({{TAG|IMIX}}=4).
Description: {{TAG|MIXPRE}} specifies the metric in the Broyden mixing scheme({{TAG|IMIX}}=4).
----
----
== Related Tags and Sections ==
*{{TAG|MIXPRE}}=0
:No preconditioning, metric=1
*{{TAG|MIXPRE}}=1
:"Inverse Kerker" metric with automatically determined {{TAG|BMIX}} (determined in such a way that the variation of the preconditioning weights covers a range of a factor 20)
*{{TAG|MIXPRE}}=2
:"Inverse Kerker" metric with automatically determined {{TAG|BMIX}} (determined in such a way that the variation of the preconditioning weights covers a range of a factor 200)
*{{TAG|MIXPRE}}=3 (implemented for test purposes; '''not''' recommended)
:"Inverse Kerker" metric with {{TAG|BMIX}} from {{FILE|INCAR}}, the weights for the metric are given by
::<math>P\left(G\right)=1+\frac{B^2}{G^2}</math>
:with <math>B</math>={{TAG|BMIX}}.
 
The preconditioning is done only on the total charge density (i.e. up+down component) and not on the magnetization charge density (i.e. up-down component). In our experience, the introduction of a metric always improves the convergence speed. The best choice is {{TAG|MIXPRE}}=1 (i.e. the default).
 
== Related tags and articles ==
{{TAG|IMIX}},
{{TAG|IMIX}},
{{TAG|INIMIX}},
{{TAG|INIMIX}},
Line 13: Line 26:
{{TAG|AMIN}},
{{TAG|AMIN}},
{{TAG|WC}}
{{TAG|WC}}
----
[[The_VASP_Manual|Contents]]


[[Category:INCAR]][[Category:Mixing]]
{{sc|MIXPRE|Examples|Examples that use this tag}}
 
[[Category:INCAR tag]][[Category:Density mixing]]

Latest revision as of 14:49, 17 October 2024

MIXPRE = 0 | 1 | 2 | 3
Default: MIXPRE = 1 

Description: MIXPRE specifies the metric in the Broyden mixing scheme(IMIX=4).


No preconditioning, metric=1
"Inverse Kerker" metric with automatically determined BMIX (determined in such a way that the variation of the preconditioning weights covers a range of a factor 20)
"Inverse Kerker" metric with automatically determined BMIX (determined in such a way that the variation of the preconditioning weights covers a range of a factor 200)
  • MIXPRE=3 (implemented for test purposes; not recommended)
"Inverse Kerker" metric with BMIX from INCAR, the weights for the metric are given by
with =BMIX.

The preconditioning is done only on the total charge density (i.e. up+down component) and not on the magnetization charge density (i.e. up-down component). In our experience, the introduction of a metric always improves the convergence speed. The best choice is MIXPRE=1 (i.e. the default).